HORIZONTAL DISCHARGE SPLIT SYSTEM HEAT PUMP-1THRU 2TON


DESCRIPTION/APPLICATION
PHYSICAL DATA
ELECTRICAL DATA
NOMINAL PERFORMANCE RATING
 
 

DESCRIPTION/APPLICATION :

  Models Series HDPF Are For Heat Pump Applications

  Modern Compact Design With Quiet Operating Horizontal Discharge Air

  Narrow Footprint Ideal For Ground Level, Rooftop, Or Wall Mounting

  Designed For Use With Typical Mini Split Indoor Sections, As Well As, Standard Air Handlers Or Indoor Coils

CONSTRUCTION :

  Steel Sheet Metal Shall Be Durable Baked Enamel Finish

STANDARD EQUIPMENT/FEATURES :

  Copper Tube, Aluminum Fin Construction

  Brass Suction And liquid Line Shut Off Valves With Flare Connections

  Liquid Shut Off-Valve Provided With Built-In Flow Rater Expansion Device

  Fully Charged For 15 Feet Tubing Length

  Line Voltage Control Circuit Suitable For Connection To Typical Mini Split Indoor Section

  Totally Enclosed Permanently Lubricated Condenser Motor

  Isolated Compressor Compartment

  Liquid Line Filter Drier Factory Installed

  Quiet Hermetically Sealed Reciprocating Compressor With Internal Overload Protection Or Rotary Compressor With External Overload Protection

PHYSICAL DATA

ITEM HDPF12-2 HDPF18-2 HDPF24-2
FAN
DIA. CM(IN) 7.1 (18) 7.1 (18) 7.1 (18)
RPM 950 950 950
COIL
FACE AREA M² (FT²) 0.73 (6.5) 0.73 (6.5) 0.73 (6.5)
TUBE DIA. MM (IN) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8)
NO. ROWS / FINS CM (IN) 1 / 7.5 (19) 1 / 7.5 (19) 1 / 7.5 (19)
NO. OF TUBES 20 20 20
FIN TYPE RIPPLED RIPPLED RIPPLED
REFRIGERANT CON.
LIQUID DIA. MM (IN) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)
SUCTION DIA. MM (IN) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8)
TYPE FLARE FLARE FLARE
WEIGHT KG (LBS) 59.5 (131) 62.7 (138) 63.6 (140)

NOTE:
SPECIFICATIONS AND PERFORMANCE DATA LISTED HERE IN ARE SUBJECT TO CHANGE WITHOUT NOTICE.

WIRING DIAGRAM
LINE VOLTAGE CONTROL CIRCUIT
(TYPICAL WIRING FOR USE WITH
DUCTLESS INDOOR SECTION)
DIMENSIONAL DATA

ELECTRICAL DATA

Model Power Supply **Minimum
Circuit
Ampacity
*Maximum
Over Current
Protection
Maximum
Volts
Minimum Volts Compressor Cond. Fan
Volts PH HZ FLA LRA Volts FLA LRA Volts
HDPF12-2 220/240 1 50 10.3 15 264 198

7.9

43

220/240

0.4 1/12 220/240
HDPF18-2 220/240 1 50 14.3 20 264 198

11.1

52

220/240

0.4 1/12 220/240
HDPF24-2 220/240 1 50 18.0 30 264 198

14.1

72

220/240

0.4 1/12 220/240

* May Use Fuses Or HACR Type Circuit Breakers Of The Same Size As Noted
** Wire Size Should Be Determined In Accordance With Local Electrical Codes. Extensive Wire Runs Will Require Larger Wire Sizes

NOMINAL PERFORMANCE RATING

COOLING PERFORMANCE
Model 95°F OD 80/67°F ID KCALH
BTUH
115°F OD 80/67°F ID KCALH
BTUH
Outdoor Indoor Total Sensible KWI Total Sensible KWI
HDPF12-2 WMH12-2 2900 2230 -- 2540 2095 --
11500 8845 1.44 10100 8315 1.92
HDPF18-2 WMH18-2 4135 3180 -- 3625 2990 --
16400 12600 2.05 14380 11860 2.74
HDPF24-2 WMH24-2 5296 3975 -- 4530 3735 --
21000 15770 2.56 17980 14820 3.43
HEATING PERFORMANCE
Model 47°F OD 80/67°F ID KCAL
BTUH
17°F OD 80/67°F ID KCAL
BTUH
Outdoor Indoor Total KWI Total KWI
HDPF12-2 WMH12-2 2770 -- 1588 --
11000 1.56 6300 1.32
HDPF18-2 WMH18-2 4290 -- 2169 --
16000 2.07 8600 1.57
HDPF24-2 WMH24-2 5170 -- 2744 --
20500 2.55 11000 2.15

- KWI = COMPRESSOR + INDOOR BLOWER + OUTDOOR FAN WATTS
- OD = OUTDOOR DRY BULB TEMPERATURE - DEGREE F
- ID = INDOOR DRY BULB/WET BULB TEMPERATURE - DEGREE F