DESCRIPTION/APPLICATION :
Models
Series HDPF Are For Heat Pump Applications
Modern
Compact Design With Quiet Operating Horizontal Discharge Air
Narrow
Footprint Ideal For Ground Level, Rooftop, Or Wall Mounting
Designed
For Use With Typical Mini Split Indoor Sections, As Well As,
Standard Air Handlers Or Indoor Coils
CONSTRUCTION :
Steel
Sheet Metal Shall Be Durable Baked Enamel Finish
STANDARD EQUIPMENT/FEATURES :
Copper
Tube, Aluminum Fin Construction
Brass
Suction And liquid Line Shut Off Valves With Flare
Connections
Liquid
Shut Off-Valve Provided With Built-In Flow Rater
Expansion Device
Fully
Charged For 15 Feet Tubing Length
Line
Voltage Control Circuit Suitable For Connection To
Typical Mini Split Indoor Section
Totally
Enclosed Permanently Lubricated Condenser Motor
Isolated
Compressor Compartment
Liquid
Line Filter Drier Factory Installed
Quiet
Hermetically Sealed Reciprocating Compressor With
Internal Overload Protection Or Rotary Compressor With
External Overload Protection
|
|
|
ITEM |
HDPF12-2 |
HDPF18-2 |
HDPF24-2 |
|
|
FAN |
|
DIA. CM(IN) |
7.1 (18) |
7.1 (18) |
7.1 (18) |
|
RPM |
950 |
950 |
950 |
|
|
COIL |
|
FACE AREA M² (FT²) |
0.73 (6.5) |
0.73 (6.5) |
0.73 (6.5) |
|
TUBE DIA. MM (IN) |
9.52 (3/8) |
9.52 (3/8) |
9.52 (3/8) |
|
NO. ROWS / FINS CM (IN) |
1 / 7.5 (19) |
1 / 7.5 (19) |
1 / 7.5 (19) |
|
NO. OF TUBES |
20 |
20 |
20 |
|
FIN TYPE |
RIPPLED |
RIPPLED |
RIPPLED |
|
|
REFRIGERANT CON. |
|
LIQUID DIA. MM (IN) |
6.35 (1/4) |
6.35 (1/4) |
6.35 (1/4) |
|
SUCTION DIA. MM (IN) |
15.88 (5/8) |
15.88 (5/8) |
15.88 (5/8) |
|
TYPE |
FLARE |
FLARE |
FLARE |
|
WEIGHT KG (LBS) |
59.5 (131) |
62.7 (138) |
63.6 (140) |
|
|
NOTE:
SPECIFICATIONS AND PERFORMANCE DATA LISTED HERE IN ARE
SUBJECT TO CHANGE WITHOUT NOTICE. |
WIRING
DIAGRAM
LINE VOLTAGE CONTROL CIRCUIT
(TYPICAL WIRING FOR USE WITH
DUCTLESS INDOOR SECTION) |
 |
|
|
DIMENSIONAL DATA |
 |
|
|
|
|
Model |
Power
Supply |
**Minimum
Circuit
Ampacity |
*Maximum
Over Current
Protection |
Maximum
Volts |
Minimum Volts |
Compressor |
Cond. Fan |
|
Volts |
PH |
HZ |
FLA |
LRA |
Volts |
FLA |
LRA |
Volts |
|
HDPF12-2 |
220/240 |
1 |
50 |
10.3 |
15 |
264 |
198 |
7.9 |
43 |
220/240 |
0.4 |
1/12 |
220/240 |
|
HDPF18-2 |
220/240 |
1 |
50 |
14.3 |
20 |
264 |
198 |
11.1 |
52 |
220/240 |
0.4 |
1/12 |
220/240 |
|
HDPF24-2 |
220/240 |
1 |
50 |
18.0 |
30 |
264 |
198 |
14.1 |
72 |
220/240 |
0.4 |
1/12 |
220/240 |
|
|
* May Use Fuses Or HACR Type Circuit
Breakers Of The Same Size As Noted
** Wire Size Should Be Determined In Accordance With Local
Electrical Codes. Extensive Wire Runs Will Require Larger
Wire Sizes |
|
NOMINAL
PERFORMANCE RATING |
|
|
COOLING
PERFORMANCE |
|
Model |
95°F OD
80/67°F ID KCALH
BTUH |
115°F OD
80/67°F ID KCALH
BTUH |
|
Outdoor |
Indoor |
Total |
Sensible |
KWI |
Total |
Sensible |
KWI |
|
HDPF12-2 |
WMH12-2 |
2900 |
2230 |
-- |
2540 |
2095 |
-- |
|
11500 |
8845 |
1.44 |
10100 |
8315 |
1.92 |
|
HDPF18-2 |
WMH18-2 |
4135 |
3180 |
-- |
3625 |
2990 |
-- |
|
16400 |
12600 |
2.05 |
14380 |
11860 |
2.74 |
|
HDPF24-2 |
WMH24-2 |
5296 |
3975 |
-- |
4530 |
3735 |
-- |
|
21000 |
15770 |
2.56 |
17980 |
14820 |
3.43 |
|
|
HEATING
PERFORMANCE |
|
Model |
47°F OD
80/67°F ID KCAL
BTUH |
17°F OD
80/67°F ID KCAL
BTUH |
|
Outdoor |
Indoor |
Total |
KWI |
Total |
KWI |
|
HDPF12-2 |
WMH12-2 |
2770 |
-- |
1588 |
-- |
|
11000 |
1.56 |
6300 |
1.32 |
|
HDPF18-2 |
WMH18-2 |
4290 |
-- |
2169 |
-- |
|
16000 |
2.07 |
8600 |
1.57 |
|
HDPF24-2 |
WMH24-2 |
5170 |
-- |
2744 |
-- |
|
20500 |
2.55 |
11000 |
2.15 |
|
|
- KWI = COMPRESSOR + INDOOR BLOWER +
OUTDOOR FAN WATTS
- OD = OUTDOOR DRY BULB TEMPERATURE - DEGREE F
- ID = INDOOR DRY BULB/WET BULB TEMPERATURE - DEGREE F |
Home